Look for links to printable pdf
literature in equipment specifications sections, above in this column, & on
site map.


| |
F72 Ducted Electronic Air Cleaner
Commercial Kitchen Hood Exhaust Electrostatic Air Cleaners brochure
(Approved for use in
New York City
commercial kitchen hood exhaust systems)
 |
 |
F72A |
F72B
(shown with optional 180 lbs carbon odor module on a skid)
|
Smokemaster Model F72A/B
High capacity electronic air cleaner for in-duct applications.
Key Benefits
- Stacking Capacity to 48,000
CFM*
- Hinged Door for Easy Cell Access
- 36 Month Parts
Warranty
|
- Solid State Dual Voltage Power Supply
- Smokemaster® Electronic Cell
- ETL listed to UL- 867 and UL- 710
|
*Inquire regarding stacking capacity beyond
48,000 CFM.
Air mover is not included. Installer must provide air mover sized to accommodate
required airflow in ductwork system.
Weight: |
Unit |
Installed |
Shipping |
|
F72A |
150 lbs. |
200 lbs. |
|
F72B |
250 lbs. |
300 lbs. |
Cabinet: |
16 gauge
galvanized steel |
Power Input: |
100-120
VAC, 50/60
Hz F72A 1003 |
|
200-240
VAC, 50/60 Hz F72A 1011 |
|
Nominal
watts 40, Max. watts 90 |
|
100-120
VAC, 50/60 Hz F72B 1003 |
|
200-240
VAC, 50/60 Hz F72B 1011 |
|
Nominal
watts 50, Max. watts 100 |
Power Supply: |
Solid
state, dual voltage and self regulating. Nominal output voltages are 9400
Vdc ionizer and 4700 Vdc on the collector section. Power supply is housed in
the hinged power door and is sealed from the air stream. |
Cell Specification:
|
Dimensions: |
24 1/4"x
24 1/8"x 10 3/4" |
|
Weight: |
60 lbs.
per cell |
|
Collection Area: |
240 sq.
ft. |
|
Voltage Gradient: |
20,000
volts per inch minimum |
|
F72A (One cell) |
F72B (Two
cells) |
Ambient Temp.: |
125 F Max,
40 F Min.
Airflow through Cells |
Mounting: |
Vertical,
standing or hanging cabinet with horizontal airflow. Horizontal mounting
with vertical airflow. |
Pre/Post Filters:
|
1"
Multi-layered aluminum mesh |
Diagnostics: |
Systems
light and test button |
|
|
F72A
RATINGS: |
|
F72B
RATINGS: |
CFM |
Efficiency |
WG |
|
CFM |
Efficiency |
WG |
|
1000
|
99% |
0.06 |
|
2000 |
99% |
0.06 |
|
1500 |
99% |
0.12 |
|
3000 |
99% |
0.12 |
|
2000 |
95% |
0.22 |
|
4000 |
95% |
0.22 |
|
2500
|
90% |
0.33 |
|
5000 |
90% |
0.33 |
|
3000 |
80% |
0.49 |
|
6000 |
80% |
0.49 |
|
Changes in design and specifications may occur without notice.
METRIC CONVERSION |
FORMULA |
Ins. to mm |
Ins. x 25.4 |
Lbs. to kgs. |
Lbs. x 0.455 |
Ins. w.g. to kPa |
Ins. w.g. x 0.2488 |
CFM to m3/h |
CFM X 1.6992 |
Ft2 to m2 |
Ft2 x 0.0929 |
- Also see
the following optional modules for gas/odor adsorption:
Pricing
Contact Us.